{"title":"Pumps for Construction \u0026 Site Dewatering","description":"\u003cp\u003eBrowse drainage pumps for groundwater, rainwater and suitable site water. Check the permitted solids size and the lift to the discharge point before choosing.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRelated collections\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/site-dewatering-pumps\"\u003eSite Dewatering Pumps\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/flood-pumps\"\u003eFlood \u0026amp; Drainage Pumps\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","products":[{"product_id":"dab-drenag-fx-submersible-pumps","title":"Drenag FX Drainage Pumps","description":"\u003ch4\u003eDAB DRENAG FX drainage pumps\u003c\/h4\u003e\n\u003cp\u003eDAB DRENAG FX 15 submersible pumps are designed for drainage of rainwater, groundwater, grey water and sandy water from civil and commercial installations. They are intended for higher-head drainage duties and meet EN 12050-2. DAB specifies a \u003cstrong\u003e10 mm free passage\u003c\/strong\u003e for the DRENAG FX range.\u003c\/p\u003e\n\u003ch4\u003eModel-specific performance\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDRENAG FX 15.07:\u003c\/strong\u003e maximum head 16.2 m at zero flow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDRENAG FX 15.11:\u003c\/strong\u003e maximum head 23.3 m at zero flow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDRENAG FX 15.15:\u003c\/strong\u003e maximum head 26.4 m at zero flow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDRENAG FX 15.22:\u003c\/strong\u003e maximum head 31.8 m at zero flow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal motor output (P2):\u003c\/strong\u003e 0.8 to 2.3 kW, depending on model.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower supply:\u003c\/strong\u003e single-phase 230 V or three-phase 400 V, 50 Hz, depending on model.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eMaximum head is measured at zero flow and is not the operating head at a selected flow rate. Please use the manufacturer hydraulic curves and the variant specification table to check the duty point.\u003c\/p\u003e\n\u003ch4\u003eConstruction and installation\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eImpeller and pump body:\u003c\/strong\u003e cast iron, with an open impeller and wear-resistant rubber disc.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical seal:\u003c\/strong\u003e double seal protected in an oil chamber.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFree passage:\u003c\/strong\u003e 10 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutlet:\u003c\/strong\u003e 1 1\/2 inch threaded GAS or flanged DN32 \/ DN40.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiquid temperature:\u003c\/strong\u003e up to +50°C, or +60°C for short periods. ATEX versions are limited to +40°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum immersion:\u003c\/strong\u003e 7 m.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable:\u003c\/strong\u003e 10 m as listed in the DAB 2026 catalogue.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl options\u003c\/h4\u003e\n\u003cp\u003eMA variants have an integrated float switch for automatic operation. MNA and TNA models do not include a float and may be operated using an appropriate external control arrangement. Three-phase motor protection must be provided by the installer. ATEX versions are available separately; do not assume a standard listed model is ATEX certified.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer reference:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.dabpumps.com\/en_en\/products\/catalog\/fx\/fx-drenag\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDAB DRENAG FX technical information\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch4\u003eDelivery\u003c\/h4\u003e\n\u003cp\u003eContact our team for the current lead time. UK mainland delivery is included as described in our delivery policy.\u003c\/p\u003e","brand":"DAB Pumps","offers":[{"title":"60191219 | DRENAG FX 15.07 MA","offer_id":53993684337025,"sku":"60191219 | DRENAG FX 15.07 MA","price":851.0,"currency_code":"GBP","in_stock":true},{"title":"60191217 | DRENAG FX 15.07 MNA","offer_id":53993684369793,"sku":"60191217 | DRENAG FX 15.07 MNA","price":834.0,"currency_code":"GBP","in_stock":true},{"title":"60191218 | DRENAG FX 15.07 TNA","offer_id":53993684402561,"sku":"60191218 | DRENAG FX 15.07 TNA","price":834.0,"currency_code":"GBP","in_stock":true},{"title":"60191239 | DRENAG FX 15.11MA","offer_id":53993684435329,"sku":"60191239 | DRENAG FX 15.11MA","price":943.0,"currency_code":"GBP","in_stock":true},{"title":"60191237 | DRENAG FX 15.11 MNA","offer_id":53993684468097,"sku":"60191237 | DRENAG FX 15.11 MNA","price":924.0,"currency_code":"GBP","in_stock":true},{"title":"60191238 | DRENAG FX 15.11 TNA","offer_id":53993684500865,"sku":"60191238 | DRENAG FX 15.11 TNA","price":924.0,"currency_code":"GBP","in_stock":true},{"title":"60191257 | DRENAG FX 15.15 MA","offer_id":53993684533633,"sku":"60191257 | DRENAG FX 15.15 MA","price":1053.0,"currency_code":"GBP","in_stock":true},{"title":"60191255 | DRENAG FX 15.15 MNA","offer_id":53993684566401,"sku":"60191255 | DRENAG FX 15.15 MNA","price":1032.0,"currency_code":"GBP","in_stock":true},{"title":"60191256 | DRENAG FX 15.15 TNA","offer_id":53993684599169,"sku":"60191256 | DRENAG FX 15.15 TNA","price":1032.0,"currency_code":"GBP","in_stock":true},{"title":"60191277 | DRENAG FX 15.22 TNA","offer_id":53993684631937,"sku":"60191277 | DRENAG FX 15.22 TNA","price":1189.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0760\/6360\/5013\/files\/DAB_DRENAG.png?v=1751461689"}],"url":"https:\/\/pumpsandgearboxesdirect.com\/collections\/pumps-for-construction-site-dewatering.oembed","provider":"Pumps and Gearboxes Direct","version":"1.0","type":"link"}