CM 40-540 T-IE3
DAB Inline Pumps
Product Description
CP2, CP2-G / DCP2, DCP2-G by DAB pumps are in-line pumps designed for air conditioning, heating, and water recirculation in commercial building services' presence of thermal solar panels (solar collectors). These pumps are available in both single and twin pump models.
Applications:
In-line pumps for use in commercial building services, industrial installations for heating and air conditioning and hot water for domestic use
Designed for water recirculation in air conditioning and heating systems, even in the presence of solar collectors.
Available in twin versions (models with letter D).
Construction Features of the Pump:
Suction and delivery ports are in line and flanged PN 10 or PN 16 with threaded connectors for control pressure gauges.
Pump body and motor support are constructed from cast iron.
Impeller material can be cast iron or technopolymer depending on the model.
Standard mechanical seal according to DIN 24960 with silicon carbide/silicon carbide and EPDM O-rings for added durability.
Construction Features of the Motor:
Air-cooled three-phase asynchronous motor with two poles.
Motor shaft is made of stainless steel.
Electrical protection is the responsibility of the user.
Technical Data
Operating range | From 1.2 to 420 m³/h with head up to 41 meters |
Pumped liquid | Clean, free of solids and abrasives, non-viscous, non-aggressive, non-crystallized, and chemically neutral, with properties similar to water. Maximum glycol content: 30% (for other glycol percentages, contact Technical Support). |
Liquid temperature range | From -10°C to +130°C for DN 40 - DN 50. From -10°C to +140°C for the remainder of the range. |
Maximum ambient temperature | +40°C |
Maximum operating pressure | PN10: for DN 40 - DN 50. PN16: For the remainder of the range. |
Flanging | PN 16 |
Special executions on request | Other voltages and/or frequencies |
Protection | IP 55 |
Insulation |
Class F |